HUAWEI TE30 Videoconferencing Endpoint
User Guide
Table 6-4 Site parameters
Parameter
Category
Type
Number
IP address
Rate
Issue 01 (2013-03-27)
Description
Specifies the category of the site.
Specifies the line the site uses to
access the videoconferencing
network.
l If you select IP, your TE30 uses
the protocol specified Preferred
IP protocol to call the site.
l If you set Category to CT site,
the available value for this
parameter is SIP.
Specifies the site number used to
place calls between sites.
l IP, E1, T1, 4E1, basic rate
interface (BRI), and H.323
phone site numbers are allocated
by the videoconferencing
service provider.
l PSTN site numbers are
telephone numbers.
Specifies the site IP address.
NOTE
This parameter is unavailable if you set
Category to IP address.
Specifies the call rate for the line
selected for a remote endpoint.
The call rates supported vary
depending on the type of the site you
wish to call.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
6 Conference
Setting
The default value is Ordinary
site.
l Ordinary site: Select this
option for a traditional
videoconferencing site.
l Telepresence site: Select
this option for a Huawei
telepresence site.
l CT site: Select this option
for a Cisco TelePresence
site.
The default value is H.323.
No default value is set for this
parameter.
No default value is set for this
parameter.
The default value is 8Mbps.
Select the highest available call
rate.