2.7.7.8. Range (Auto False Echo Suppression Distance)
2.7.7.9. Shaper Mode (default Off)
1.
This parameter cannot be reset to the factory default.
Page 94
SITRANS Probe LU (PROFIBUS PA) – INSTRUCTION MANUAL
Defines the endpoint of the Learned TVT distance.
a.
Go to
b.
Determine the actual distance from the reference point (transducer
face) to the material surface.
c.
Subtract 0.5 m (20") from this distance, and enter the result.
Display before Auto False Echo Suppression
default TVT
curve
false
echo
Display after Auto False Echo Suppression
TVT curve
(learned)
false
echo
Turns TVT Shaper on or off. (For use only by Siemens Milltronics
personnel.)
true
TVT
echo
Hover Level
Distance (meters)
material
level
Distance (meters)
Doc Id: VM11
Active Date: 15/12/2006
1
: (default 1)
.
7ML19985JB02