Sony HMI-3000MT Instructions For Use Manual page 33

Head mounted image processor unit
Hide thumbs Also See for HMI-3000MT:
Table of Contents

Advertisement

Video does not display in 3D.
Miscellaneous
There is no audio.
The on/standby button on the
image processor unit blinks
(orange) continuously.
The HMM indicator on the image
processor unit blinks (orange)
continuously.
The buttons on the head mounted
monitor are unresponsive.
"DEMO" appears at the top right
of the setup menu screen.
Cannot change the language
setting due to the setup menu
being in an unfamiliar language.
• If similar images appear side-by-side horizontally or vertically on the display, the cables
for the 3D video may not be connected properly. For details, see "Connections"
(page 21).
• 3D perception varies among individuals.
• If the [3D Display] menu appears but video is not displayed in 3D, turn off the connected
device that is outputting the 3D video and turn it on again.
• This unit does not support 2D to 3D conversion (i.e., simulated 3D).
• Check the settings on the connected medical device.
This unit does not include an audio output function. Connection of headphones and similar
equipment is also not supported.
• If the indicator blinks twice every 3 seconds, the head mounted monitor, image processor
unit, or cables may be damaged. For details, contact your Sony service representative.
• If the indicator blinks three times every 3 seconds, the image processor unit is
overheated. Wait a moment for the unit to cool off. Do not obstruct the ventilation holes
on the image processor unit, and ensure proper ventilation. If the above problem
persists, contact your Sony service representative.
• If the indicator blinks twice every 3 seconds, the head mounted monitor, image processor
unit, or cables may be damaged. For details, contact your Sony service representative.
• If the indicator blinks three times every 3 seconds, the image processor unit is
overheated. Wait a moment for the unit to cool off. Do not obstruct the ventilation holes
on the image processor unit, and ensure proper ventilation. If the above problem
persists, contact your Sony service representative.
• If the indicator blinks four times every 3 seconds for 1 minute, the head mounted monitor
is overheated. Wait a moment for the unit to cool off. If the above problem persists,
contact your Sony service representative.
• If the indicator blinks five times every 3 seconds for 1 minute, both the head mounted
monitor and the image processor unit are overheated. Wait a moment for the units to
cool off. If the above problem persists, contact your Sony service representative.
The buttons on the head mounted monitor do not function unless the unit is mounted.
Contact your Sony service representative.
• If you have not completed initial setup, press the b repeatedly to return to the language
selection screen, and then select your language.
• If you completed initial setup, restore the factory default settings as follows, and select
your language while performing initial setup again.
1 Press the MENU button to display the setup menu.
2 Press the V button to select the [General Setup] icon.
3 Press the B button to move the cursor to the right.
4 Press the V button to move the cursor to the very bottom.
5 Press the MENU button. (The confirmation message for [Restore to factory settings]
will appear.)
6 Press the b button, and then press the MENU button. (The unit will restart.)
7 When initial setup begins, press the v/V button to select your language, and then
press the B button to confirm.
8 Follow the instructions on the screen to complete initial setup.