Hitachi Relion 670 Series Product Manual page 173

Line differential protection
Hide thumbs Also See for Relion 670 Series:
Table of Contents

Advertisement

Line differential protection RED670
Version 2.2
Table 256. Scheme communication functions
Function
Scheme communication logic for distance or overcurrent
protection
Phase segregated scheme communication logic for distance
protection
Current reversal and weak-end infeed logic for distance protection
Current reversal and weak-end infeed logic for phase segregated
communication
Local acceleration logic
Scheme communication logic for residual overcurrent protection
Current reversal and weak-end infeed logic for residual
overcurrent protection
Direct transfer trip
1)
Only one of ZCPSCH/ZPCPSCH can be selected.
2)
Only one of ZCRWPSCH/ZPCWPSCH can be selected.
Table 257. Logic
Position
L
Table 258. Logic functions
Function
Configurable logic blocks Q/T
Extension logic package
Table 259. Monitoring
Position
1
M
Table 260. Monitoring functions
Function
Circuit breaker condition monitoring
Fault locator
Through fault monitoring
Current harmonic monitoring, 3 phase
Voltage harmonic monitoring, 3 phase
Single and double ended fault locator
1)
Only one of LMBRFLO / SMTRFLO can be selected.
2)
Function SMTRFLO require line data communication in 2Mbps mode.
Table 261. Station communication
Position
1
2
3
P
Table 262. Station communication functions
Function
IEC 61850-9-2 Process bus communication, 8 merging units
IEC 62439-3 Parallel redundancy protocol
IEC 62439-3 High-availability seamless redundancy
Synchrophasor report, 8 phasors
Rapid spanning tree protocol
1)
PRP, HSR and RSTP require two SFPs placed in pairs.
2)
This functionality requires accurate time synchronization, therefore either 'Precision Time Protocol (PTP) Time synch or GTM or IRIG-B will be required.
Hitachi Energy
Function
identification
ZCPSCH
ZPCPSCH
ZCRWPSCH
ZPCWPSCH
ZCLCPSCH
ECPSCH
ECRWPSCH
DTT
1
Function
identification
2
3
1
0
Function
identification
SSCBR
LMBRFLO
PTRSTHR
CHMMHAI
VHMMHAI
SMTRFLO
4
5
6
7
0
0
0
0
Function
identification
PRP
HSR
RSTP
© 2017 - 2022 Hitachi Energy. All rights reserved
Ordering no
1MRK005920-AC
1MRK005920-BB
1MRK005920-CA
1MRK005920-DB
1MRK005920-EA
1MRK005920-FB
1MRK005920-GA
1MRK005921-AY
2
Ordering no
1MRK005922-MX
1MRK005922-DB
4
5
Ordering no
1MRK005924-HA
1MRK005925-XC
1MRK005924-TA
1MRK005924-QB
1MRK005924-SB
1MRK005925-XD
8
9
10
11
0
0
0
0
Ordering no
1MRK005933-HC
1MRK005932-FA
1MRK005932-NA
1MRK005933-DA
1MRK005933-SA
1MRK 505 379-BEN R
Position
Available
Selected
qty
qty
1
0-2
2
0-2
3
0-2
4
0-2
5
0-1
6
0-1
7
0-1
8
0-1
3
00
Position
Available
Selected
qty
qty
1
0-1
2
0-1
6
Position
Available
Selected
qty
qty
1
00-06
2
1
4
0–2
5
0–3
6
0–3
7
1
12
13
14
15
0
0
0
Position
Available
Selected
qty
qty
1
0-1
2
0-1
3
0-1
15
0-1
18
0-1
Notes and rules
1)
2)
Notes and rules
7
Notes and rules
1)
1)
2)
16
17
18
0
0
Notes and rules
1)
2)
1)
173

Advertisement

Table of Contents
loading

This manual is also suitable for:

Relion red670

Table of Contents