Download Print this page

Cutting Unit Drive Lever Assembly - Toro Greensmaster eFlex 1021 Service Manual

Hide thumbs Also See for Greensmaster eFlex 1021:

Advertisement

Cutting Unit Drive Lever Assembly

g336962
1.
V-ring seal
2.
Reel lever handle rod
3.
Knob
4.
Retaining ring
5.
Control shaft clamp (2 each)
6.
Socket head screw (4 each)
7.
Extension spring (2 each)
8.
Control cover
9.
Bolt and washer assembly (8 each) 18.
Disassembling the Cutting Unit Drive Lever Assembly
Controls, Wheels, and Accessories : Service and Repairs
10.
Lower handle cover
11.
Reel cable
12.
Split bushing
13.
Cotter pin clip
14.
Link assembly
15.
Main control shaft
16.
Split bushing
17.
Socket cap
Cotter pin clip
Note: Refer to
Figure 82
1. Ensure that the cutting-unit-drive lever is in the D
machine on a level surface, release the clutch bail, engage the service and
parking brake, rotate the key switch to O
the Operator's Manual.
Figure 82
19.
20.
21.
22.
23.
24.
25.
26.
27.
during this procedure.
FF
Page 6–10
Clevis connector
Clevis pin (4 each)
Extension spring
Shoulder screw
Reel lock lever assembly
Bail latch spacer
Upper receiver weldment
Flange nut
Reel lever assembly
position, park the
ISENGAGE
, and remove the key; refer to
Greensmaster
20248SL Rev C
®
eFlex 1021

Advertisement

loading

This manual is also suitable for:

04861