en | System setup - hardware
Circuit overloading
Consideration should be given to the connection of the equipment to the power supply
circuitry and the effect that any possible overloading of circuits might have on overcurrent
protection and power supply wiring. Appropriate consideration of equipment nameplate
ratings should be used when addressing this concern.
Reliable ground
A reliable ground must be maintained at all times. To ensure this, the rack itself should be
grounded. Particular attention should be given to power supply connections other than the
direct connections to the branch circuit (i.e. the use of power strips, etc.).
3.4

Rack mounting instructions

This section provides information on installing the chassis into a rack unit. There are a variety
of rack units on the market, which may mean the assembly procedure will differ slightly. You
should also refer to the installation instructions that came with the rack unit you are using.
Notice!
This rail will fit a rack between 26" and 33.5" deep.
3.4.1

Identifying the sections of the rack rails

You should have received two rack rail assemblies in the rack mounting kit.
Each assembly consists of two sections:
Two pairs of short brackets to be used on the front side of the outer rails are also included.
3.4.2

Installing the inner rails

Both the left and right side inner rails have been pre-attached to the chassis. Proceed to the
next step.
2013.10 | V1 | DOC
an inner fixed chassis rail that secures directly to the system chassis
an outer fixed rack rail that secures directly to the rack itself.
Quick Installation Guide