'Uncoated'
Customer defined
At 'Halftone', select which halftone you want to calibrate.
2.
'Normal'
'Fine'
'Error diffusion'
At 'Media', select which media you want to calibrate.
3.
Touch 'OK' to print the calibration chart.
4.
An instruction window opens.
Follow the instructions carefully and touch 'Next'.
5.
A few calibration charts are printed. Make sure you use the last printed calibration chart.
An instruction window opens.
Calibrate the spectrometer according to the instructions on the operator panel.
6.
Place the spectrometer in the holder, press the button to calibrate the spectrometer,
and wait for 5 seconds.
Take 5 blank sheets of the same media you used for the calibration chart, and put
them underneath the last printed calibration chart.
Measure the calibration sheet according to the instructions on the operator panel.
7.
Perform the following actions per color.
Position the spectrometer at the indicated position.
Hold down the spectrometer button and wait for the arrow.
Scan the column with patches smoothly in about 2 seconds.
Touch 'OK' to save the calibration results.
8.
Select one of the following options.
9.
Touch 'Yes' and 'OK' to calibrate another media family / halftone combination.
Touch 'No' and 'OK' to stop the media family calibration.
Touch 'Finish' to finish the calibration procedure.
10.
Calibrate the printer - 1. Shading correction , on page 362
Calibrate the printer - 2. Auto gradation adjustment , on page 364
Calibrate the controller - '3. Media family calibration'