Mitsubishi Electric MELSECQ Series User Manual page 55

Multichannel high-speed counter module
Hide thumbs Also See for MELSECQ Series:
Table of Contents

Advertisement

4
PROCEDURES AND SETTINGS BEFORE
OPERATION
Downloaded from
ManualsNet.com
(Example) Target channel: channel 1, pulse input mode setting: 1 multiple of 2
phases, counting speed setting: 200 kPPS, counter format: ring counter, and present
value selection setting: setting value B
Set the switch 1
Set the switch 3
Set the switch 4
POINT
The reserved bits in Table 4.7 are for system use, not for users.
Therefore, always fix them to 0. If used (changed from 0 to 1) by a user, the
operations of the QD63P6 are not ensured.
(2) Details of the intelligent function module switch setting
Table 4.8 Details of the intelligent function module switch setting
Setting item
Pulse input mode
Counting speed setting
Counter format
Present value selection
setting
search engine
0003
.
H
0002
.
H
0101
.
H
Description
Set the pulse input mode for each channel.
When setting 6
to F
, a switch setting error (error
H
H
code: 810) occurs. (Refer to Section 8.5.)
Set the counting speed for each channel.
(When setting 11 (3
), a switch setting error (error
H
code: 810) occurs. (Refer to Section 8.5.)
Set the counter format for each channel.
Set the same storage location of the present counter
value (present value A (Un\G10 and 11)/present
value B (Un\G200 and 201)) to all channels.
4.5 Intelligent Function Module Switch Setting
1
2
3
4
Reference
Section 5.1.1
Section 3.1
5
Section 5.2.1
Section 5.2.2
Section 3.4.2 (5)
6
7
8
4
- 15