(3) Setting example
(a)
Starting the interrupt program of the master station (station number 0) when
RX100 turns on
The following is a setting example to execute the interrupt program corresponding
to the interrupt pointer I50 when RX100 turns on by turning on the corresponding
switch on the slave station side.
CPU module
Interrupt program
execution
SM400
I50
Interrupt
2)
processing
IRET
1) Set the interrupt setting parameters for the Simple Motion module (station
number 0) in the "Interrupt Settings" window as shown below.
2) Set the parameters in the "Intelligent Function Module Interrupt Pointer
Setting" window as shown below.
POINT
By using link special relay (SB) and link special register (SW) as an interrupt
condition device, an interrupt program can be started in case of data link error.
(Refer to Appendix 2, Refer to Appendix 3.)
Simple Motion module
Master station
(Station No.0)
1)
ON
RX100
1)
2)
7 - 29
Chapter 7 PARAMETER SETTING
Slave station
(Station No.17)
ON
Set the same SI No. as the interrupt setting.
Switch