To predict and remove pollutants:
AIC Auto Mode
Automatic operation combines the AIC Learning Function and AIC Patrolling Function to
predict the pollution of the room.
Panel indicators
Operation indicators
AIC
Air quality
indicator
indicators
Flickering
Blue
Flashing
(3-second
intervals)
Blue Ð red,
or
red
Blue Ð red,
Lit
or
red
Blue
Operation indicators
Air quality monitor
Operating status
AIC Auto Mode
in progress.
The air purifier is running
according to the prediction
of the AIC learning function;
or the AIC patrolling function
is re-circulation of the air.
Pollutant is being
detected.
AIC Auto Mode
in progress.
The fan speed corresponds to
the level of pollution detected.
AIC Auto Mode stopped.
The air purifier is not operating.
Panel indicators
Super alleru-
buster indicator
(blue)
AIC indicator
(orange)
Mega active
ion indicator
(green)
When AIC Auto Mode is off,
the super alleru-buster indicator, mega active
ion indicator, and fan speed indicators are off.
AIC learning function and AIC patrolling
function cannot operate independently.
AIC learning function
This function memorizes the degree of air
pollution of a room every 20 minutes in all
operation modes except "Stop" mode.
The unit will operate based on previous day's
memory and the expected pollution level.
If the room air appears to be dirtier than
predicted, the fan speed will be adjusted
according to the level of pollution detected
at that time. When the air becomes clean,
operation will stop automatically.
Although the memory is updated daily with
the newest pollution level detected,
all memory is erased when the power plug
is disconnected.
AIC patrolling function
If AIC automatic operation remains stopped
for 50 minutes, patrol operation starts.
(The unit will start to circulate the room air
at a fan speed of Super.)
If pollutant is detected, operation will start
at the fan speed that corresponds to the
level of pollution detected.
When the air becomes clean, operation will
stop automatically. If automatic operation
remains stopped for 50 minutes, the patrol
operation will restart.