LG SV-iC5 Series Instruction Manual page 81

Lg inverter instructions manual
Hide thumbs Also See for SV-iC5 Series:
Table of Contents

Advertisement

Accel/Decel pattern setting
Group
LED display
Function
F 2
group 1
F 3
H17
H18
Accel/Decel pattern is settable at F2 and F3.
Linear : This is a general pattern for constant torque applications
S-curve : This curve allows the motor to accelerate and decelerate smoothly.
Appropriate applications: Elevator door, lifts..
☞ Caution :
For S-curve, the actual Accel/Decel time takes longer than the time set by user.
Accel/Decel
Ref. Freq.
Freq
Parameter name
[Accel pattern]
[Decel pattern]
S-Curve accel/decel start
side
S-Curve accel/decel end
side
Freq.
Run
command
Accel time
H17
H18
Accel
Accel
Starting
Ending
Min/Max
range
0
Linear
1
S-curve
1~100
Decel time
H17
H18
Decel
Decel
Starting
Ending
9-13
9. Basic functions
Set value
Unit
0
40
%
40
%
1/2 of
Accel/Decel Ref.
Freq