Reliability Test; Test Conditions; Specifications - Toshiba LTA057A341F Specification

Table of Contents

Advertisement

6.6 Reliability Test

6.6.1 Test Conditions

1) The module should be driven and inspected under normal test conditions.
2) The module should not have condensation of water (moisture) on the module.
3) The module should be inspected after two or more hours storage in normal conditions
(15 to 35°C,45 to 65%(RH)).
4) A module shall be used only for one test.

6.6.2 Specifications

The module shall have no failure in the following reliability test items.
Test Item
High Temperature Operation
High Temperature Storage
High Temperature
High Humidity operation
Low Temperature Operation
Low Temperature Storage
2)
Temperature Shock
2)
Mechanical Vibration
2)
Mechanical Shock
Note 1) Operating
Note 2) Non-Operating
Definitions of failure for judgment shall be as follows:
1) Function of the module should be maintained.
2) Current consumption should be smaller than the specified value.
3) Appearance and display quality should not have distinguished degradation.
4) Luminance should be larger than 50% of the minimum value specified in 5.2.
Toshiba Matsushita Display Technology Co.,Ltd
Specification No. TENTATIVE
1)
70°C
2)
80°C
60°C
1)
1)
-20°C
2)
-30°C
-30°C ⇔ 80°C
0.5h
10 - 200 - 10Hz sweep/cycle,
1.5×9.8m/s
X, Y, Z each directions, 0.5h each
50×9.8m/s
+/-X, +/-Y, +/-Z direction,
one time each
Test Conditions
192 h
192 h
90% 192 h
192 h
192 h
50 cycles
0.5h
2
constant,
2
, 11ms,
Date: 2008 – 11- 07
Date:
-
-
←# Special
Result
OK
OK
OK
OK
OK
OK
OK
OK
New No. LTA057A341F-14
Old
No.
←& Addition
Sheet
29
3p/3p
3p/3p
3p/3p
3p/3p
3p/3p
3p/3p
3p/3p
3p/3p
← Change