Inspection
on/oFF sWITCh
1. Remove switch from recoil base and detach leads from
terminals.
2. Using an ohm meter measure the resistance between
terminals 1 and 2 with the switch in the ON position(|). The
ohm meter should read approximately infinity.
3. Using an ohm meter measure the resistance between
terminals 1 and 2 with the switch in the OFF position (O).
The ohm meter should read approximately zero.
4. If either of the tests described here yield a different result
replace the switch.
30