Technical Data; General; Dc Voltage; Ac Voltage (50 Hz - 400 Hz) - Acer PASAR 323 Instruction Manual

Digital multimeter
Table of Contents

Advertisement

7.0 Technical data

7.1 General

Display
Overload indication
Measurement rate
Low battery indication
Auto Power Off
Overvoltage catagory
Pollution degree
Working temperature
Storage temperature
Altitude
Power Supply
Fuses
Dimensions
Weight

7.2 DC Voltage

Range
Resolution
400mV
0.1mV
4V
1mV
40V
10mV
400V
100mV
600V
1V
7.3 AC Voltage (50 - 400 Hz)
Range
Resolution
4V
1mV
40V
10mV
400V
100mV
600V
1V

7.4 Current 10A/15A

Range
Resolution
10A/15A 10mA
10A continious working, 15A for 30 s with cool down time of 5 min.
Acoustic signal: >10A.
3½ digit, LC Display, 3999 digits
left "OL" is displayed
3 measurements per second
Battery symbol at approx. 2.5V
after approx. 15 min
CAT III 600V
2
0 - +50°C max. 80% rel. humidity
-10 - +60°C max. 80% rel. humidity
up to 2000 m
2 batteries 1.5V, IEC LR03
200mA/250V fast acting, 5 x 20 mm
10A/250V fast acting, 5 x 20 mm
170 x 85 x 50 mm
approx. 410 g
Accuracy
±(0,8%+3 digits)
Input inpedance: 10M Ω
Accuracy
±(1,3%+3 digits)
Input inpedance: 10M Ω
Accuracy
±(2%+3 digits)
1 0
Overload protection
600V AC/DC
Overload protection
600V AC/DC
Overload protection
approx. 0,03V/A

Advertisement

Table of Contents
loading

Table of Contents