Parameter Settings Of Camera Recorder Module - Mitsubishi Electric MELSEC iQ-R Series Introduction Manual

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

4.2

Parameter Settings of Camera Recorder Module

Use GX Works3 to configure the parameter setting of the camera recorder module.
For details on the parameter setting screen, refer to the following.
MELSEC iQ-R System Recorder User's Manual (Application)
Module parameter
Set the module parameters for the camera recorder module in the module parameter screen. When using multiple camera
recorder modules, specify one as the main module and the others as sub modules.
For details on the multiple module configuration, refer to the following.
MELSEC iQ-R System Recorder User's Manual (Startup)
Operating procedure
1.
Set the module parameters for the camera recorder module.
[Navigation] window  [Parameter]  [Module Information]  [RD81RC96-CA(Target module)]  [Module Parameter]
 [Basic Settings]
IP address: 192.168.3.49
Ex.
Recording operation setting: Main
When a recording file is saved in the SD memory card, the camera recorder module and personal computer
must be connected via Ethernet to read the recording file. Therefore, set the IP address and subnet mask for
the camera recorder module.
2.
Write the parameters to the CPU module.
For the detailed procedure, refer to the following.
Page 46 Writing
4 PROGRAMMABLE CONTROLLER SETTINGS
4.2 Parameter Settings of Camera Recorder Module