Mains connection:
Route the cable through the screwed cable gland and connect to terminals L1, N, PE
Alarm tapping:
There is a potential-free alarm relay (changeover) available to forward the alarm in the event of a malfunction:
Route the cable through the second screwed cable gland and connect it
N.C. – COM:
Contact closed in the event of a malfunction or power failure (fail-safe principle)
N.O. – COM:
Contact opened in the event of a malfunction or power failure
Tighten screwed cable gland(s)
in place, check correct fit and tighten the screws