Toshiba e-STUDIO163 Service Manual page 127

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO163:
Table of Contents

Advertisement

(3)
Remove 2 screws and take off the toner
motor.
[C] Main motor drive unit
(1)
Take off the Process unit.
P.11-9 "[A] Process unit"
(2)
Take off the toner motor with the bracket.
(3)
Remove 2 screws and take off the registra-
tion roller holder.
Note:
When installing the registration roller holder,
align the arm of the registration roller clutch
with the rotation stopper of the registration
roller holder.
(4)
Remove 1 clip and take off 1 bushing.
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Bracket
Fig. 9-5
Registration roller holder
Rotation stopper
Fig. 9-6
Clip
Bushing
Fig. 9-7
9 - 7