Kenwood TK-290 Service Manual page 47

Hide thumbs Also See for TK-290:
Table of Contents

Advertisement

TK-290
Item
Condition
16. DTMF
1) Set panel tuning mode
deviation
CH No. : 3
adjustment
Signalling No. : 1
(narrow)
Select DTDV
in panel tuning mode
Turn the toggle SW to the
right (narrow)
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
PTT : ON
17. MSK
1) Set panel test mode
deviation
CH No. : 3
adjustment
Signalling No. : 1
(wide)
Select MSDV
in panel tuning mode
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
PTT : ON
18. MSK
1) Set panel tuning mode
deviation
CH No. : 3
adjustment
Signalling No. : 1
(narrow)
Select MSDV
in panel tuning mode
Turn the toggle SW to the
right (narrow)
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
PTT : ON
19. Transmission 1) Set panel test mode
S/N check
CH No. : 3
(wide)
Signalling No. : 1
Deviation meter filter setting
LPF : 300Hz
HPF : 3kHz
De-emphasis : 750µs
PTT : ON
20. Transmission 1) Set panel test mode
S/N check
CH No. : 3
(narrow)
Signalling No. : 1
Turn the toggle SW to the
right (narrow)
Deviation meter filter setting
LPF : 300Hz
HPF : 3kHz
De-emphasis : 750µs
PTT : ON
21. BATT
1) Set panel test mode
detection
CH No. : 3
writing
Signalling No. : 1
Select BATT
in panel tuning mode
PTT : ON
46
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power meter Panel
ANT
Panel
Deviation
meter
Oscilloscope
AG
Side
Universal
AF VTVM
Power meter Panel
ANT
Side
DC VTVM Bottom BATT
terminal
Adjustment
Parts
Method
± 50Hz
Top1/
1.5kHz
Top2
± 50Hz
3.00kHz
± 50Hz
1.50kHz
Check
42dB or more
37dB or more
Orange Write the voltage
6.2V
level
Specifications/Remarks

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents