154
en | Troubleshooting
Supervise:
1.
2.
P
7- Tamper
–
Condition:
Onboard panel tamper input is open.
Restore:
4
Supervise:
1.
2.
P
–
Condition:
Keypad 1 is open and the tamper contact is triggered.
Restore:
4
Supervise:
1.
2.
P
–
Condition:
A disassembly of DX2010 module 1, 2, 3, 4, 5, or 6 is detected and the occurrence of zone
extension module 1, 2, 3, 4, 5 or 6 is considered as a tamper condition.
Restore:
4
Supervise:
1.
2.
P
2015.05 | 06 | F.01U.309.277
Report the fault to configured destination on address 124 when the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).
When the fault is reset, send the restored report to the configured destinations.
The FAULT indicator is turned off when there is no other system fault.
System Tamper
Close the panel tamper input and reset the fault.
Report the tamper condition to configured destination on address 124 when the tamper
condition is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).
When the tamper condition is reset, send the restored report to the configured
destinations.
The FAULT indicator is turned off when there is no other system fault.
Keypad 1-16 Tamper
Close the keypad and reset the tamper condition.
Report the tamper condition to configured destination on address 124 when the tamper
condition is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).
When the tamper condition is reset, send the restored report to the configured
destinations.
The FAULT indicator is turned off when there is no other system fault.
Zone Expansion Module 1-6 Tamper
Restore the DX2010 module 1, 2, 3, 4, 5, or 6 to a normal condition and reset the fault.
For more information, refer to DX2010, page 16.
Report the tamper condition to configured destination on address 0124 when the tamper
condition is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).
When the tamper condition is reset, send the restored report to the configured
destinations.
The FAULT indicator is turned off when there is no other system fault.
Installation Manual
AMAX panel
Bosch Sicherheitssysteme GmbH