9. Installation
9.2 Selection of the best location
Install the air conditioner in the location that satisfies the
following conditions.
• The place shall easily bear a load exceeding four times
the indoor unit's weight.
• The place shall be able to inspect the unit as given in
the figure.
• The place where the unit shall be leveled.
• The place shall allow easy water drainage.
(Suitable dimension "H" is necessary to get a slope to
drain as figure.)
• The place shall easily connect with the outdoor unit.
• The place where the unit is not affected by an electrical
noise.
• The place where air circulation in the room will be good .
• There should not be any heat source or steam near the
unit.
• The servicing inspection hole in the ceiling should be as
large as the product.
• The selection of the servicing hole should be approved
by the customer.
20 _
Ceiling concealed duct - Middle static pressure(2)
Indoor unit
Top view
(Unit: mm)
Inspection hole
600 x 600
Air inlet vents
Control box
600
1000
Air outlet vents
Front
Side view
(unit: mm)
• Suitable dimension "H" is necessary to get a slope
to drain as shown in the figure
600
20 or more