Page 2
Revision Chapter Page Revision 1 to 4 1 to 2 1 to 6 1 to 10 1 to 2 SIREMOBIL Compact Register 3 SPR2-130.033.02 Page 2 of 4 Siemens AG System Manual Rev. 02 12.98 TD SD 24 Medical Engineering...
Remaining work ........3-9 4 _______Changes to previous version ______________________________________ 4-1 Siemens AG Register 3 SPR2-130.033.02 Page 3 of 4 SIREMOBIL Compact Medical Engineering Rev. 02 12.98 TD SD 24 System Manual...
Page 4
0 - 4 Contents This page intentionally left blank. SIREMOBIL Compact Register 3 SPR2-130.033.02 Page 4 of 4 Siemens AG System Manual Rev. 02 12.98 TD SD 24 Medical Engineering...
Viscogen KL300, 40 g 73 95 353 Conductive paste for heat sink Lifting column parts kit 37 79 407 G5429 Siemens AG Register 3 SPR2-130.033.02 Page 1 of 2 SIREMOBIL Compact Medical Engineering Rev. 02 12.98 TD SD 24 System Manual...
Page 6
1 - 2 General This page intentionally left blank SIREMOBIL Compact Register 3 SPR2-130.033.02 Page 2 of 2 Siemens AG System Manual Rev. 02 12.98 TD SD 24 Medical Engineering...
• Remove the spacers from the 6 screws. • Open the strain relief for ribbon cable X 4 (2/Fig.2). Siemens AG Register 3 SPR2-130.033.02 Page 1 of 6 SIREMOBIL Compact Medical Engineering Rev. 02 12.98 TD SD 24 System Manual...
Page 8
2 - 2 Removing the lifting column Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 SIREMOBIL Compact Register 3 SPR2-130.033.02 Page 2 of 6 Siemens AG System Manual Rev. 02 12.98 TD SD 24 Medical Engineering...
Remove the stabilization bracket of the monitor cable connector from the lifting column by removing the screws , 1/Fig.7. Siemens AG Register 3 SPR2-130.033.02 Page 3 of 6 SIREMOBIL Compact Medical Engineering Rev. 02 12.98 TD SD 24 System Manual...
Page 10
2 - 4 Removing the lifting column Fig. 8 Fig. 9 Fig. 10 Fig. 11 Fig. 12 Fig. 13 SIREMOBIL Compact Register 3 SPR2-130.033.02 Page 4 of 6 Siemens AG System Manual Rev. 02 12.98 TD SD 24 Medical Engineering...
(1/Fig.14). Siemens AG Register 3 SPR2-130.033.02 Page 5 of 6 SIREMOBIL Compact Medical Engineering Rev. 02 12.98 TD SD 24 System Manual...
Page 12
Remove the four mounting screws of the lifting column from the underside of the unit; tilt the unit a little, if necessary. • Remove the lifting column (two people required). Be careful not to damage the connection cable. SIREMOBIL Compact Register 3 SPR2-130.033.02 Page 6 of 6 Siemens AG System Manual Rev.
Place the lifting column into the guide (1/Fig.1) on the chassis and secure it with the screws from underneath the unit (screw torque = 40 Nm). Siemens AG Register 3 SPR2-130.033.02 Page 1 of 10 SIREMOBIL Compact Medical Engineering Rev. 02 12.98 TD SD 24 System Manual...
Page 14
3 - 2 Installing the lifting column Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 Fig. 8 SIREMOBIL Compact Register 3 SPR2-130.033.02 Page 2 of 10 Siemens AG System Manual Rev. 02 12.98 TD SD 24 Medical Engineering...
Page 15
Lift the C-arm back out of the mounting (3 people required) (Fig.5) and place it on a table. • Remove the C-arm mounting again from the lifting column (1/Fig.4) by removing the screws. Siemens AG Register 3 SPR2-130.033.02 Page 3 of 10 SIREMOBIL Compact Medical Engineering Rev. 02 12.98 TD SD 24 System Manual...
Reattach (3/Fig.9) the protective conductor to the chassis (on the control side from below left). • Reinstall the cover plate (on the control panel side at the chassis, under the control lever) SIREMOBIL Compact Register 3 SPR2-130.033.02 Page 4 of 10...
Secure the cover plate with the screws under the swivel brake. • Reattach the hand railing to the C-arm with the screws. Siemens AG Register 3 SPR2-130.033.02 Page 5 of 10 SIREMOBIL Compact Medical Engineering Rev. 02 12.98 TD SD 24 System Manual...
Connect the BNC cable. Installing the power pack M 14 • Install the base plate. • Install the power pack with the plug connections facing down. SIREMOBIL Compact Register 3 SPR2-130.033.02 Page 6 of 10 Siemens AG System Manual Rev. 02 12.98...
Secure board D2 with the spacers Fig.15. • Install the interface plate. • Position the spacers on the 6 screws. Siemens AG Register 3 SPR2-130.033.02 Page 7 of 10 SIREMOBIL Compact Medical Engineering Rev. 02 12.98 TD SD 24 System Manual...
Page 20
• Reattach the bracket (2/Fig.17) to the lifting column and tighten the screws. • Connect the footswitch cable to board D3 and secure it with the strain relief (Fig.18). SIREMOBIL Compact Register 3 SPR2-130.033.02 Page 8 of 10 Siemens AG System Manual Rev.
Install all the covers. When doing this, attach the protective conductors to the covers. Perform the protective conductor test. Siemens AG Register 3 SPR2-130.033.02 Page 9 of 10 SIREMOBIL Compact Medical Engineering Rev. 02 12.98 TD SD 24 System Manual...
Page 22
3 - 10 Installing the lifting column This page intentionally left blank. SIREMOBIL Compact Register 3 SPR2-130.033.02 Page 10 of 10 Siemens AG System Manual Rev. 02 12.98 TD SD 24 Medical Engineering...
Page 23
Retighten the lock nuts so that the screws do not shift. TD PS 24 / Rottner TD SD 24 / Groß SMS, Iselin / O’Donnell Siemens AG Register 3 SPR2-130.033.02 Page 1 of 2 SIREMOBIL Compact Medical Engineering Rev. 02 12.98 TD SD 24 System Manual...
Page 24
4 - 2 Changes to previous version This page intentionally left blank. SIREMOBIL Compact Register 3 SPR2-130.033.02 Page 2 of 2 Siemens AG System Manual Rev. 02 12.98 TD SD 24 Medical Engineering...