6 Transport and storage

There are no special transport instructions for this product. However, always observe
chapter 2 "Safety instructions" and comply with the environmental conditions
specified in the data sheet for storage and transport.

6.1 Storing the valve with IO-Link interface

The valve is supplied in good order and condition.
Under the following conditions, the valve can be stored up to 12 months:
Do not store the valve outdoors but in a well-ventilated room.
Store the valves between +5 °C and +40 °C.
For the purpose of short-time transportation, the ambient temperature range
according to the data sheet shall apply.
Protect the valve against humidity, particularly ground humidity. Store the valve
on a shelf or on a pallet. The relative air humidity must not exceed 65% and there
must not be any condensation.
Ensure that no ozone formation takes place near the storage location.
Provide for 100% UV protection.
Store the valve in packaging in order to protect it from dust and dirt.
All connections at the valve must be closed with cap elements.
After opening the transport packaging, it must be closed properly again for
storage. Use the original packaging for storage.
Do not remove the covers of the hydraulic ports of the valve before assembly.
In case of storage of more than six months or in case sea transport is necessary,
please consult Bosch Rexroth.
RE 29118-B/09.2021; 4WRPEH6_3X, 4WRPEH10_3X, 4WRPE6_3X, 4WRPE10_3X, 4WRLE_4X; Bosch Rexroth AG