Hitachi HF-W6500 45/40 Feature Manual page 154

Hide thumbs Also See for HF-W6500 45/40:
Table of Contents

Advertisement

● Status
Shows the currently set status of each simulated hardware device. The following
shows a list of statuses for each hardware device.
PS fan, Front fan, CPU fan
Internal Temperature
Drive bay1, Drive bay2
DIMM A, DIMM B
(*) D Model only
Immediately after the Simulation Tool window starts, all hardware devices are set
to "Normal" or "Healthy".
● Setting
Shows a new status to be simulated for each target hardware device.
If no status to be simulated is set, "---" is displayed. (Immediately after the
Simulation Tool window starts, "---" is displayed for all hardware devices.)
● Apply button
If you click this button, all "Setting" are applied to the "Status" of hardware
devices.
The monitoring function of the RAS software detects change in the "Status" of the
hardware devices and notifies the change through various interfaces.
NOTE
A new hardware status is applied to the notification interface of the RAS
software when the following time elapses after you click Apply in the
Simulation Tool window. Wait for the time specified below before you check the
result of simulation.
・Fan condition: About 10 seconds later
・Temperature condition inside the chassis: About 15 seconds later
・Drive condition: About 5 seconds later
・Memory condition: About 10 seconds later
Target
8-7
8. SIMULATING THE HARDWARE STATUS
Status
Normal, Error
Normal, Error
Healthy, SMART Detected,
Overrun, Not Connected,
Offline (*), Rebuild (*)
Normal, Error, Not Mounted