Details For Ordering; Technical Data; Troubleshooting - Siemens CIL0050-30 Installation Instruction

Ir illuminator
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

Details for ordering

Type
Item number
CIL0050-30
S54561-C801-A1
CAIL0050-PA
S54561-B851-A1
CHBS2310
2GF1705-8LE
CHBA0211
2GF1705-8LH

Technical data

Power requirements
Power consumption
Fuse
Output power
Photoelectric switch relay output
Telemetry input
Camera voltage output
Adjustable IR power
Angle of light source
Range
Spectral emission
Weight
Relative humidity
Ambient temperature, operation
Ambient temperature, storage
Dimensions (L x W x D)
Protection rating
Approvals
MTBF
Cable glands
4
Siemens Building Technologies
Fire Safety & Security Products
Description
IR lamps 30 – 60°
PSU adapter for pole mount
Aluminum wall mount with integral
swivel-tilt joint
Pole adapter for CHBS2310 mounts
PSU: 100 – 230 V AC
PSU: 50 W (on max. power)
T 2.5 A
PSU: 2.4 A at 13.5 V
max. 120 V AC / 24 V DC, 1 A
Control input (no-voltage input,
floating contact)
12 V DC / 1 A
10 – 100 %
30 – 60°
Max. 100 m
850 nm, Class 1 LED to EN 60825-1
PSU: 1.65 kg
Illuminator: 2.50 kg
Approx. 80 %
-20 to +50 °C
-30 to +60 °C
PSU: 160 x 160 x 81 mm
Illuminator: 210 x 150 x 63 mm
IP66, IK10 (IR illuminators)
CE, C-Tick
70.000 h
4 x M16 (min. 4.5 mm, max. 10 mm
cable dia.)

Troubleshooting

Ensure all tests are carried out by a qualified, trained engineer. Ensure
safe working practices are followed at all times.
1. Basics
Check polarity of infrared lamp connection
(red = lamp+, black = lamp-).
Check if telemetry inputs are linked by bridge.
Check if the photoelectric switch is working.
Check setting by turning power potentiometer fully clockwise.
Check mains input.
Check fuse to ensure it is intact.
2. Set up camera, lens and illumination.
Check alignment of lamp.
Check camera lens – fully open at night and set correctly.
EN
04.2009

Advertisement

Table of Contents
loading

Table of Contents