Commissioning

For the voltage supply, use a 24 V industrial power supply unit acc. to DIN
EN 60742, classification VDE 551, for example "VAP01.1H-W23-024-010-
NN" (part number R911171065).
10.10.4 Total connection diagram - Power supply unit, UPS and control
cabinet PC
230V~
24V
Ext. power supply
230 V
Fig. 10-24: Total connection diagram - Power supply unit, UPS and control cabinet PC
11 Commissioning
11.1 IT security
The
operation
of
implementation of an integral concept for state-of-the-art IT security. Bosch
Rexroth products are part of this integral concept. Bosch Rexroth product
characteristics have to be taken into consideration in an integral IT security
concept. The relevant characteristics are documented in the IT security guideline
(R911342562).

11.2 Configuring the extension modules "RS-422/RS-485"

The extension module "RS-422/RS-485" has to be configured before use.
Therefore, a jumper "CN2" and a slide switch are available at "SW1".
Bosch Rexroth AG R911384699_Edition 03
XCOM
+
+
-
24 V
Out
24 V
USV
installations,