Standards

7.3.2 Input system or multi-touch front

The maximum permissible number, type and size of defects on the front, on the
glass or between the display and the front – such as trapped dust, dirt and
scratches is defined in the FT quality guideline.
8 Standards
The products have been developed according to the current German edition of
the standards at the time of product development.

8.1 Standards used

Standard
EN 60204 -1
EN 61000-6-4
EN 61000-6-2
EN 60068-2-6
EN 60068-2-27
EN 61010-1
Tab. 8-1: Standards used

8.2 FCC

This device was tested and complies with the limit values for a digital device of
class A as per part 15 of the FCC rules. These limit values should ensure an
appropriate protection against harmful interferences if the device is operated in
an industrial area. This device creates and uses high-frequency, it can radiate it
and it can cause harmful interferences of the wireless communication if it is not
installed and used as specified in the operating instructions. Harmful
interferences can result if this device is operated on a residential area. In this
case, the user has to eliminate the interferences at his own expense.
This device complies with part 15 of the FCC rules. Operation is subject to the
following two conditions:
This device may not cause harmful interferences.
This device has to tolerate any receiving interferences, including interferences
that can cause undesired operation.

8.3 CE marking

8.3.1 Declaration of conformity

The electronic products described in these instructions comply with the
requirements and the target of the following EU directive and the following
harmonized European standards:
Bosch Rexroth AG R911384699_Edition 03
IndraControl PR4 and VR4 Control cabi-
Description
Safety of machinery – Electrical equipment of machines
Generic standards – Emission standard (industrial environments)
Generic standards – Noise immunity (industrial environments)
Vibration test
Shock test
Safety requirements for electrical equipment for measurement, control
and laboratory use - Part 1: General requirements