Program 10: System Configuration Setup
SA
1530
SB
Description
Use Program 10-03 : PCB Setup to setup and confirm the Basic Configuration data for each PCB.
When changing a defined terminal type, first set the type to '0' and then plug the new device in to have the system
automatically define it, alternatively redefine the type manually.
Program 10-03 allows the editing of installed units (PCB's), you can not edit the settings if the slot is unused, install
the PCB first then edit the settings.
Note: The items highlighted in grey are read only and cannot be changed.
Input Data
Slot Number
1.
For HBIU(308M/308E/008E Unit)
Physical Port Number
Prog. No.
10-03-01
Terminal Type
10-03-02
Logical Port Number(see Note 1)
10-03-03
Transmit Gain Level for SLT
Receive Gain Level for SLT
10-03-04
Note 1) Reference and a setup are possible only for a Station port.
2.
For 2PGDU Unit
Physical Port Number
Prog. No.
Item
10-03-01
Terminal Type
10-03-02
Logical Port Number
10-03-03
Relay setting(see Note 1)
Note 1) The Relays can be assigned up to 2 ports for a 2PGDU Unit.
Item
0 : No setting
1 : Multi-Line Telephone
2 : Single Line Telephone
10 : DSS Console
13 : Trunk
3-9,11,12 : -Not Used-
Station : 0-72
Trunk 0-51
1-63(-15.5.......+15.5dB)
1-63(-15.5.......+15.5dB)
Physical port Number 1-2
0 : No setting
8 : Doorphone
(1-7,10,11 : -Not Used-)
Physical port Number 3-4
0 : No setting
6 : External Speaker
7 : External Trunk Audible
9 : External Music Source(MOH or BGM)
(1-5,8,10,11 : -Not Used-)
0-6
0-4
(0 : Not Used)
15
10-03: PCB Setup
1-18
Extension : 1-8
Trunk : 9-11
Input data
1-4
Input data
Programming Manual
Default
0
0
32(0dB)
32(0dB)
Default
Physical port 1-2: 8
Physical port 3-4 : 6
0
Relay No.1 : 1
Relay No.2 : 2