Mitsubishi Electric 800 Series Installation Manualline page 36

Inverter for fans and pumps
Hide thumbs Also See for 800 Series:

Advertisement

BASIC OPERATION
Parameter Name
Station number in
1124
inverter-to-inverter
link
Number of inverters in
1125
inverter-to-inverter
link system
Pre-charge change
1132
increment amount
Second pre-charge
1133
change increment
amount
Second PID display
1136
bias coefficient
Second PID display
1137
bias analog value
Second PID display
1138
gain coefficient
Second PID display
1139
gain analog value
Second PID set point/
1140
deviation input
selection
Second PID measured
1141
value input selection
Second PID unit
1142
selection
1143
Second PID upper limit
1144
Second PID lower limit
Second PID deviation
1145
limit
Second PID signal
1146
operation selection
Second output
1147
interruption detection
time
Second output
1148
interruption detection
level
Second output
1149
interruption cancel
level
1150
PLC function user
to
parameters
1 to 50
1199
PID gain tuning
1211
timeout time
Step manipulated
1212
amount
Step responding
1213
sampling cycle
Timeout time after the
1214
maximum slope
Limit cycle output
1215
upper limit
Limit cycle output
1216
lower limit
1217
Limit cycle hysteresis
PID gain tuning
1218
setting
PID gain tuning start/
1219
status
30
Setting Range
Initial Value
9999
0 to 5, 9999
2
2 to 6
9999
0 to 100%, 9999
9999
0 to 100%, 9999
9999
0 to 500, 9999
20%
0 to 300%
9999
0 to 500, 9999
100%
0 to 300%
2
1 to 5
1 to 5,
3
101 to 105
9999
0 to 43, 9999
9999
0 to 100%, 9999
9999
0 to 100%, 9999
9999
0 to 100%, 9999
0 to 7, 10 to 17
0
1 s
0 to 3600 s, 9999
0 Hz
0 to 590 Hz
1000%
900 to 1100%
0
0 to 65535
100 s
1 to 9999 s
1000%
900 to 1100%
1 s
0.01 to 600 s
10 s
1 to 9999 s
1100%
900 to 1100%
1000%
900 to 1100%
0.1 to 10%
1%
0, 100 to 102,
111, 112, 121,
0
122, 200 to 202,
211, 212, 221,
222
(0), 1, 8,
0
(9, 90 to 96)
Parameter Name
1300
to
1343
Communication option parameters
1350
to
1359
Detection time for PID
1361
output hold
1362
PID output hold range
1363
PID priming time
Stirring time during
1364
sleep
1365
Stirring interval time
1366
Sleep boost level
Sleep boost waiting
1367
time
Output interruption
1368
cancel time
Check valve closing
1369
completion frequency
Detection time for PID
1370
limiting operation
PID upper/lower limit
1371
prewarning level
range
PID measured value
1372
control set point
change amount
PID measured value
1373
control set point
change rate
Auxiliary pressure
1374
pump operation
starting level
Auxiliary pressure
1375
pump operation
stopping level
Auxiliary motor
1376
stopping level
PID input pressure
1377
selection
PID input pressure
1378
warning level
PID input pressure
1379
fault level
PID input pressure
1380
warning set point
change amount
PID input pressure
1381
fault operation
selection
Starting times lower 4
1410
digits
Starting times upper 4
1411
digits
Motor induced voltage
1412
constant (phi f)
exponent
Second motor induced
1413
voltage constant
(phi f) exponent
Ethernet communica-
1424
tion network number
Setting Range
Initial Value
5 s
0 to 900 s
9999
0 to 50%, 9999
9999
0 to 360 s, 9999
15 s
0 to 3600 s
0 h
0 to 1000 h
9999
0 to 100%, 9999
0 s
0 to 360 s
0 to 360 s
0 s
9999
0 to 120 Hz, 9999
0 s
0 to 900 s
9999
0 to 50%, 9999
5%
0 to 50%
0 to 100%
0%
1000%
900 to 1100%
1000%
900 to 1100%
9999
0 to 100%, 9999
9999
1 to 3, 9999
20%
0 to 100%
9999
0 to 100%, 9999
5%
0 to 100%
0
0, 1
0
0 to 9999
0
0 to 9999
9999
0 to 2, 9999
0 to 2, 9999
9999
1
1 to 239

Advertisement

loading

This manual is also suitable for:

Fr-f846 e2-l2 seriesFr-f800-e