WIRING

2 WIRING
2.1 Terminal connection diagrams
CA type
Source logic
Main circuit terminal
Control circuit terminal
MCCB
3-phase
AC power
supply
*1
Control input signals
Forward rotation start
Reverse rotation start
Start self-holding selection
High speed
Multi-speed
Middle
speed
selection
Low speed
Jog operation
Second function selection
Output stop
Reset
Terminal 4 input selection
(Current input selection)
Selection of automatic restart
after instantaneous power failure
Common for external power
supply transistor
Contact input common
24 V DC power supply
24 V external power supply input
Common terminal
Frequency setting signals (Analog)
3
Frequency setting
2
potentiometer
Ω
*4
½ W, 1 k
1
(+)
Auxiliary input
(-)
Terminal 4 input
(+)
(Current input)
(-)
Connector for plug-in option
connection
Safety stop signal
Safety stop input (Channel 1)
Safety stop input (Channel 2)
Safety stop input common
For footnotes *1 to *8 refer to next page.
4
Jumper
P1
P/+
MC
R/L1
Inrush current
limit circuit
S/L2
T/L3
ON
EMC filter
ON/OFF
connector
OFF
Earth
Main circuit
(Ground)
Control circuit
STF
STR
STP(STOP)
RH
RM
RL
JOG
*2
RT
MRS
RES
AU
CS
SD
24V
PC
+24
Voltage/current
SD
input switch
ON
10E(+10V)
OFF
10(+5V)
2
0 to 5VDC
Initial value
2
0 to 10VDC
selectable
4 to 20mADC
5
(Analog common)
Initial value
0 to ±10VDC
1
0 to ±5VDC
selectable
Initial value
4 to 20mADC
4
0 to 5VDC
selectable
0 to 10VDC
Connector 2 *8
Connector 1
Connector 3
24V
Shorting wire
PC
S1
Output
S2
shutoff circuit
SIC
SD
Brake unit
(option)
N/-
U
V
W
*7
C1
B1
Relay output 1
(Fault output)
A1
C2
B2
Relay output 2
A2
RUN
Running
SU
Up to frequency
IPF
Instantaneous power failure
OL
Overload
FU
Frequency detection
SE
Open collector output common
Sink/source common
PU
connec-
tor
USB A
connec-
tor
*3
F/C
USB mini
(CA)
B
4
connec-
tor
*3
Ethernet
AM
connec-
*8
tor
5
*3
*3
So(SO)
Safety monitor output
SOC
Safety monitor output common
Motor
M
Earth (Ground)
*5
Relay output
*6
Open collector output
(+)
Analog current output
(0 to 20 mA DC)
(-)
(+)
Analog signal output
(0 to ±10 V DC)
(-)