11. Place the membrane [27] in the membrane seat [24].
24
21
12. Insert the pressure spring [28] in the membrane
28
21
13. Place the membrane cap [21] with pressure
24
31
17
14. Insert the solenoid valve core [19] into the core guide
19
21
24
BEKOMAT
13, 13 CO, 13 CO PN25, 13 CO PN40
®
cap [21].
spring [28] (not shown) onto the membrane seat.
Make sure that the pressure spring is fitted in the
centre of the membrane.
pipe [17]. Guide the flange [31] with screws over
the core guide pipe [17] and screw tightly on the
membrane cap [21].