Xg3, Motor Temperature Monitoring And Motor Holding Brake - Bosch rexroth IndraDrive Mi KCU02 Project Planning Manual

Drive systems
Hide thumbs Also See for rexroth IndraDrive Mi KCU02:
Table of Contents

Advertisement

192/407
Connection points
6.5.4

XG3, motor temperature monitoring and motor holding brake

Function
View
Bosch Rexroth AG R911335703_Edition 04
WARNING
The standard motor holding brake provided or an external motor holding
brake controlled directly by the drive controller are not sufficient on their own
to guarantee personal safety!
Personal safety must be achieved using higher-level, fail-safe measures:
Block off danger zones with safety fences or safety guards
Additionally secure vertical axes against falling or dropping after
switching off the motor power by, for example,
mechanically securing the vertical axes
adding external braking/arrester/clamping mechanisms
ensuring sufficient equilibration of the vertical axes
WARNING
The input of the motor temperature evaluation is not galvanically isolated
from the housing. Excess voltage at the input (e.g., by the motor winding
voltage flashing over) can get to the housing. Make sure that the temperature
sensor of the connected motor is double-insulated from the motor winding.
NOTICE
Only the allowed control voltage for the device is allowed at the motor
temperature evaluation input. Excess voltage at the input can damage the
device.
Connection point XG3 contains the connections for
Monitoring the motor temperature
Controlling the motor holding brake
Via an integrated contact element (BR), the power section
switches the voltage of the external 24 V supply to the output for
controlling the motor holding brake.
Connection
1
2
3
4
Tab. 6-42:
Pin assignment
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
Dangerous movements! Danger to persons
from falling or dropping axes!
Lethal electric shock from live parts with more
than 50 V!
Risk of damage to device from excess
voltage at motor temperature evaluation
input!
Signal name
MotTemp+
Motor temperature
MotTemp-
+24VBr
Output for controlling the
motor holding brake
0VBr
Function
evaluation input

Advertisement

Table of Contents
loading