Synchronous servomotors for potentially explosive areas

Advertisement

DOK-MOTOR*-MSK*EXGIIK3-PR09-EN-P
Synchronous Servomotors MSK For Potentially Explosive Areas
13
Installation
13.1
Safety
WARNING
Work required on the electric system may only be carried out by skilled elec‐
tricians. Tools for electricians (VDE tools) are absolutely necessary.
Prior to commencing work:
1. Isolate (even auxiliary circuits).
2. Protect the system or plant against restart.
3. Ensure de-energization.
4. Ground and short-circuit.
5. Cover or shield any adjacent live parts.
Before starting to work, check with an appropriate measuring device whether
parts of the system are still under residual voltage (e.g. caused by capacitors,
etc.). If yes, wait until these parts have discharged.
CAUTION
Do only use suitable lifting devices (e.g. lifting sling belts, eyebolts, chain sus‐
pension ...).
Use protective equipment and personal protective clothing (gloves, safety
shoes, ...).
Never walk under hanging loads.
Carry out all work steps with particular care. This minimizes the risk of acci‐
dents and damage.
Bosch Rexroth AG
Danger! Electric voltage! Operations in the vi‐
cinity of live parts are extremely dangerous.
Injuries due to improper handling during
transport of motors!