OPERATING CONTROLS HANDSET CONTROLS Antenna RDL (Redial) button Liquid Crystal Display (LCD) CID (Caller ID) button TALK button Press to enter the caller ID mode. Number 1 button 0-9, , Dial buttons Used for long distance dialing. TONE button Number 8 ( ) button (time button) PAUSE button Used to display the date and time of the received calls.
ALIGNMENT PROCEDURE Test Mode For Base Unit To change the unit to TEST mode, set the TONE/PULSE switch to PULSE position and press the PAGE key continuously for 2 seconds while resetting by turning the power on. When entered the TEST mode, the CHARGE LED turns off, the IN USE LED will light and the unit enters TEST mode 1.
Page 5
Test Mode For Handset Unit To perform the TEST mode, turn the power ON by pressing the “ ” and “#” buttons at the same time. When entered the TEST mode, the bell rings and the unit enters TEST mode 1 . ( Refer to the following table. ) 1.
Page 6
Base Unit Transmitter Section Connection BASE MAIN PCB AF GEN. BASE RF PCB Test Point Power Meter DC IN TEL Line Test Point 1kHz 45mV 9V Jack Jack Test Point Frequency Counter AC 120V DC 9V Adapter 60Hz Deviation Meter Preset Place the Base unit in VCO/TX FREQ.
Page 7
Receiver Section Connection BASE RF PCB BASE MAIN PCB AC Voltmeter Dummy Load RF SG (600-ohm) TEL Line DC IN Test Point Jack 9V Jack DC Voltmeter AF Terminal DC 9V AC 120V AC Adapter 60Hz Preset Place the Base unit in VCO/TX FREQ. ADJ mode in accordance with the procedure on page 3. Alignment Procedure Step Preset to...
Page 8
Handset Unit Transmitter Section Connection HANDSET RF PCB HANDSET MAIN PCB AF GEN. Test Point Power Meter Battery Test Point 1kHz 10.5mV MIC + Pin Terminals Test Point Frequency Counter DC Power Supply Deviation DC 3.8V Meter Preset Place the Handset in VCO/TX FREQ. ADJ mode in accordance with the procedure on page 4. Alignment Procedure Step Adjustment...
Page 9
Receiver Section Connection HANDSET MAIN PCB AC Voltmeter Oscilloscope HANDSET RF PCB Dummy Load RF SG (150-ohm) J602 Battery Test Point Connector Terminals J601 DC Voltmeter DC Power Supply AF Terminal DC 3.8V Preset Place the Handset in RX SENS mode (step 4) in accordance with the procedure on page 4. Alignment Procedure Step Preset to...
TROUBLESHOOTING HINTS 1. The bell does not ring. When the PAGE SW of the See 2. The bell does not base is pressed, does the ring & page does not ring. ringer on the handset ring? When the TEL SG is joined Check IC4 and TEL network with the base to make bell circuit.
Page 19
2. The bell does not ring & page does not ring. Can the base and handset See 3. The base and be connected? handset cannot be connected. Press handset DIAL key When the key of the Check IC603. while in TALK MODE. handset is pressed, can the Can key touch sound be pulse output at pin 58 of...
Page 20
3. The base and handset cannot be connected. Check IC5 and its Check whether the base is peripheral circuit. able to set in the test mode 1. Check the TX POWER and Check base RF unit. the TX FREQUENCY on the base unit.
Page 21
Set the handset in the test Check whether there is a Check VR601, R619, R632, mode 3, check whether 250Hz data waveform at R634, R635, R636 deviation of the TX data is pin 9 of J601. and C611. app. 7 kHz Dev. Check handset RF unit.
Page 22
4. Cannot make a phone call (pulse). See 3. The base and Can the base and handset handset cannot be be connected? connected. While in TALK MODE, Check IC5. press dial key of the handset. Check whether square waveform from pin 58 of IC5 is fed.
Page 23
6. Voice cannot be transmitted to other party (outgoing call). See 3. The base and Can the base and handset handset cannot be be connected? connected. Check Q608 and its The 1 kHz, 12.5 mV sine peripheral circuit. waveform is applied to MC601 side, can the 1 kHz sine waveform from...
Page 24
7. The voice of the caller cannot be heard (incoming call). See 3. The base and Can the base and handset handset cannot be be connected? connected. Check the base TEL-line The 1 kHz 77.5 mV sine circuit and RELAY control waveform is applied to circuit.
EXPLODED VIEW AND MECHANICAL PARTS LIST Base, Unit Note: To remove the RF Assembly from the unit, remove four screws 24 . Three screws 23 are used for fastening the Shield Cases 26 and 27 .
Page 40
Base Unit LOC. PART NO. REF. NO. DESCRIPTION RC008040 GNBZ458919Z Button, Push for FT-8808 RC008856 GNBZ458579Z Button, Push for FT-8808BK RC008897 GCAS458497Z Case, Battery for FT-8808 RC005680 GCAS257882Z Case, Battery for FT-8808BK RC008039 GCAS258917Z Case, Bottom for FT-8808 RC008853 GCAS158576Z...
Page 41
Handset Note: To remove the RF Assembly from the unit, remove four screws 69 . Three screws 68 are used for fastening the Shield Cases 70 and 71 .
Page 42
PART NO. REF. NO. DESCRIPTION RC008915 RBLD458506Z Blind for FT-8808 RC008714 RBLD457881Z Blind for FT-8808BK RC008044 GNBZ458923Z Button, Function for FT-8808 RC008705 GNBZ357892Z Button, Function for FT-8808BK RC008912 GNBZ458504Z Button, Push for FT-8808 RC008706 GNBZ457891Z Button, Push for FT-8808BK RC008042...
PARTS LIST PRODUCT SAFETY NOTE: Products marked with a have special characteristics important to safety. Before replacing any of these components, read carefully the product safety notice of this service manual. Don’t degrade the safety of the product through important servicing. Symbol Symbol ±...
Page 44
LOC. PART NO. DESCRIPTION RC001632 BCXT813335Z CERAMIC 0.033UF 50V K B RC001068 BCXT811025Z CERAMIC 0.001UF 50V K B RC002224 BCXK811040Z CERAMIC 0.1UF 50V Z F RC004008 BCBH813314Z CERAMIC 330PF 50V J CH RC002849 BCXK512240Z CERAMIC 0.22UF 25V Z F RC002849 BCXK512240Z CERAMIC 0.22UF 25V Z F...
Page 45
LOC. PART NO. DESCRIPTION C213 RC005208 BCML814725Z CERAMIC 0.0047UF 50V K B C214 RC005205 BCML811035Z CERAMIC 0.01UF 50V K B C215 RC005205 BCML811035Z CERAMIC 0.01UF 50V K B C216 RC005215 BCMM812704Z CERAMIC 27PF 50V J CH C217 RC005216 BCMM813304Z CERAMIC 33PF 50V J CH C218 RC005202...
Page 46
LOC. PART NO. DESCRIPTION C259 RC005217 BCMM813314Z CERAMIC 330PF 50V J CH C260 RC004185 BCSS951006Z TANTALUM CHIP 10UF 7V M A C-241 C261 RC005218 BCMM814091Z CERAMIC 4PF 50V C CH C262 RC008753 BCMM812098Z CERAMIC 2PF 50V B CH C263 RC005360 BCMM816092Z CERAMIC 6PF 50V D CH C265...
Page 47
LOC. PART NO. DESCRIPTION C518 RC005202 BCML311045Z CERAMIC 0.1UF 16V K B C519 RC005223 BCMS812091Z CERAMIC 2PF 50V C CK C520 RC005205 BCML811035Z CERAMIC 0.01UF 50V K B C521 RC005216 BCMM813304Z CERAMIC 33PF 50V J CH C522 RC005204 BCML811025Z CERAMIC 0.001UF 50V K B C523 RC008755...
Page 48
LOC. PART NO. DESCRIPTION C565 RC005216 BCMM813304Z CERAMIC 33PF 50V J CH C566 RC005204 BCML811025Z CERAMIC 0.001UF 50V K B C567 RC008752 BCML512735Z CERAMIC 0.027UF 25V K B C568 RC005218 BCMM814091Z CERAMIC 4PF 50V C CH C569 RC005216 BCMM813304Z CERAMIC 33PF 50V J CH C570 RC005218...
Page 49
LOC. PART NO. DESCRIPTION C623 RC002229 BCXT511045Z CERAMIC 0.1UF 25V K B C624 RC001069 BCXT811035Z CERAMIC 0.01UF 50V K B C625 RC001069 BCXT811035Z CERAMIC 0.01UF 50V K B C626 RC001071 BCXT813325Z CERAMIC 0.0033UF 50V K B C627 RC001071 BCXT813325Z CERAMIC 0.0033UF 50V K B C628 RC001069...
ASSEMBLY PARTS LIST NOTE: Following part numbers are not available as replacement parts. Order parts necessary for repair or contact the Toshiba Factory Service Center. LOC. PART NO. DESCRIPTION RC008049 AC200BLBA BASE MAIN ASSEMBLY RC008746 AD846BLBB BASE RF ASSEMBLY RC008050...
SPECIFICATIONS Measurement Conditions Standard Voltage: DC 3.8 V ±0.025 V Handset Unit AC 120 V ±3 V 60 Hz Base Unit 25 °C ±5 °C Temperature: Channel: Portable (TX Frequency) Base (TX Frequency) 902.080435MHz 925.989636MHz 902.130671MHz 926.039871MHz 902.180906MHz 926.090107MHz 902.231142MHz 926.140342MHz 902.281377MHz 926.190577MHz...
Page 64
Base Unit Receiver Unit Nominal Limit −115 < −107 Sensitivity 12dB SINAD (CCITT Filter ON) −1.5 −5.5 ~ +2.5 Frequency Response 0.3 kHz −3.5 −7.5 ~ +0.5 3.0 kHz Distortion at 1 mV RF Input < 5 S/N ratio at 1 mV RF Input (CCITT Filter ON, Compander ON) >...
Page 67
MECHANICAL PARTS LIST TOSHIBA AMERICA CONSUMER PRODUCTS, INC. 82 TOTOWA ROAD, WAYNE, N.J. 07470 TOSHIBA HAWAII, INC. 327 KAMAKEE ST., HONOLULU, H.I. 96814...