Bosch LTE65 Manual page 13

Telemetry system
Table of Contents

Advertisement

Bosch Motorsport
Note the following parameters and their settings
– WDServer folder – this is the folder where the ".INI" files for WDServer are stored.
Please make note of this folder path as this path will need to be referenced by WD-
Server in order to enable telemetry live viewing and logging.
– Project Key – The project key is a data security function that is used by WinDarab to
differentiate data from different users. This key should always be a 4 character hexa-
decimal value.
– Configure on Device: Select the device which will be the master for telemetry
– Type: Select your telemetry unit type
– Mode: Select Ethernet or Serial depending on your desired input configuration. Mo-
dem must also be configured accordingly.
– Baud rate: Set to desired board rate. Rate of up to 200 kBit/s is possible with Ethernet
telemetry. For serial data input, baud rates under 115 kBit/s must be selected.
– Destination IP: Do not change from above value unless specifically instructed.
– Destination Port: The logger sends for telemetry to this port. Do not change from
above value unless specifically instructed
– In a new Calibration/Measuring window, 'telemetry_state' should be viewed. This will
inform you about the data out streaming status.
– Channel setting examples:
Column1
Distance Channel
Lap Number Channel
Lap Fuel Channel (optional)
Lap Time Channel
Lap Distance Channel (optional)
Telemetry_System_LTE65_Manual
MS6/MS7/C60/C70
disttrip
Laptrigger_lapctr_dls
Fuel_fuellapold_dls
Laptrigger_laptimeold_dls
Laptrigger_lapdist_dls
Tools | 4
MS5
distlap
lapctr
fuellap
laptimeold
13 / 28