Miscellaneous; Tool Charging - Bosch TPA 300 User Manual

Hide thumbs Also See for TPA 300:
Table of Contents

Advertisement

en-US | 4 6 | User Guide | TPA 300

Miscellaneous

1

Tool Charging

Low Battery Indication
Battery indicator status:
The TPMS Tool incorporates a low battery
detection circuit. Battery life is an average
of 300 sensor tests per battery charge
(approximately 60 to 80 vehicles).
When low, icon is flashing, the tool
will turn off after 10 seconds.
DO NOT use the tool with low battery status because the transmission and emission
may not be reliable.
USB B Cable
Wall charger
USB B Socket
For charging the tool, directly plug the supplied USB cable to the tool and plug the
wall charger to an appropriate outlet. The battery icon will change to reflect the
charging status:
Battery Replacement
Unscrew the two
screws on the back of
the tool.
Remove the cap.
Unplug the battery
and change the
battery to a new one.
Reinstall the cap and
the screws.
Recycle the used battery, see Battery and Recycling dedicated section in this
user manual
© Bosch Automotive Service Solutions Inc.
1699502721 | REV. A | MAY 2020