Service and support for booksize C/D-type

7.2 Replacing the fan

7.2.2
Replacing the fan
Note
Service life and replacement intervals of the fan module
The modules have an operating hours counter (p0251). When the maximum operating
duration is reached, a corresponding message is output (A30042).
The fan modules of the Motor Modules can be ordered as replacement parts.
Table 7- 1
Module width
50 mm
50 mm
100 mm
100 mm
Required tools:
● Torx screwdriver T20
● Slotted screwdriver 0.8 x 5.5 mm
Replacing the fan for 50 mm modules (3 A ... 24 A, 2 x 3 A ... 2 x 9 A)
Removing the existing fan module
Remove the shield connection clamp.
Screwdriver: slotted, 0.8 x 5.5 mm
138
Fan modules as replacement part when replacing a fan
Type
3 A ... 18 A
2 x 3 A ... 2 x 9 A
24 A
30 A / 2 x 18 A
45 A / 60 A
Release the catch of the motor con-
nector and pull the connector out of the
Motor Module (possibly applies to 2
motor connectors).
Article No.
6SL3162-0AN00-0AA0
6SL3162-0AS00-0AA0
6SL3162-0AP00-0AA0
6SL3162-0AT00-0AA0
Remove the shield connection plate
from the Motor Module.
Screwdriver: Torx 20
Power Units in Booksize C/D-Type Format
Manual, 12/2018, 6SL3097-5AC20-0BP0
Rated fan volt-
age
24 V
12 V
24 V