■For user frame registration: Registration data byte count designation area (Un\G6912, 6953)
• The initialization data or data for connection can be registered in the buffer memory as well as the flash ROM of C24.
Data type
Initialization data
Data for connection
A registration number to register data for initialization or data for connection to the buffer memory is in the range of -32767 to
-32737 (8001H to 801FH) respectively, which is determined by the area to be used.
• In this area, the number of bytes for the data for initialization or data for connection (for 1 data) to be registered in the buffer
memory is designated.
• For more information on how to register data for initialization or data for connection in the buffer memory, refer to the
following sections.
(Page 177 Register/read/delete data for initialization, Page 181 Register/read/delete data for connection)
Buffer memory address
■For user frame registration: User frame specification area (Un\G6913 to 6952, 6954 to 6993 )
• Designate the applicable data (for 1 data) for the above registration data byte count when registering the data for
initialization or data for connection in the buffer memory.
• For more information on how to register data for initialization or data for connection in the buffer memory, refer to the
following sections.
(Page 177 Register/read/delete data for initialization, Page 181 Register/read/delete data for connection)
Buffer memory address
■Auto modem initialization designation (Un\G8199)
• Designate whether the modem on the C24 side is initialized automatically or not.
• Registration in this area is performed with Engineering tool.
The modem is initialized automatically when C24 starts up after the CPU module restarts.
■Modem initialization DR (DSR) signal enable/disable designation (Un\G8200)
Set "DR signal enabled" for this setting.
This setting is used to designate how the DR (DSR) signal is treated only when modem initialization is performed. Following
the completion of modem initialization, data is sent according to the status of the DR (DSR) signal.
■Complete signal handling for modem function designation (Un\G8201)
Set "Turn ON/OFF X13, X14" (default value) for this setting.
7 COMMUNICATIONS BY THE MODEM FUNCTION
164
7.3 Specifications of Modem Function
Registration destination
Flash ROM
Buffer memory
Flash ROM
Buffer memory
b15
Un\G6912
Un\G8142
b15
Un\G6913
Data for initialization or data for connection
to
(Area for registration number 8001H)
Un\G6952
Un\G8143
Data for initialization or data for connection
to
(Area for registration number 801FH)
Un\G8182
Data registered by the operating
system
User-registered data
(All registered by user)
(All registered by user)
(All registered by user)
b0
to
0 to 78/80
0 to 78/80
0: No registration data
1 to 78: Registration data exists (for initialization)
80: Registration data exists (for connection)
to
b0
Registration number (Decimal
(Hex.))
2000 to 2013 (7D0H to 7DDH)
2500 to 2529 (9C4H to 9E1H)
-32767 to -32737 (8001H to 801FH)
3000 to 3029 (BB8H to BD5H)
-32767 to -32737 (8001H to 801FH)
(Number of bytes)