Huawei RTN 380H Quick Installation Manual page 11

Table of Contents

Advertisement

Installing the RTN 380H
3
XPIC Installation
1.
XPIC installation applies only to the RTN 380H housing MXXI5.
Retain removed caps for future use.
2.
Cover unused ports with caps/PG covers.
3.
Before installing the RTN 380H, remove the protective cover and film on the antenna port. Otherwise, the signal transmission will be affected.
4.
Different methods can be used to change the polarization direction of antennas. If the method provided in this document is not suitable for the type of antenna you have, use the method provided in the installation manual delivered with your antennas.
5.
The polarization direction of antennas is vertical by default. If the planned polarization direction is horizontal, change the polarization direction to horizontal.
6.
If an antenna with a diameter of 0.2 m, 0.3 m or 0.6 m is used in a direct mount scenario, you may install the RTN 380H on the antenna and then hoist them both into position on the tower.
7.
Before installing a cable, bind the cable section that links the cable connector to the pole. This will protect the cable connector from damage. Be sure that the length of cable running from the binding point to the RTN 380H is sufficient to attach the cable connector to
the Ethernet service port on the RTN 380H.
8.
To facilitate installation, install cables from left to right.
Installation procedure
Follow the antenna use instructions to
1
install the antenna.
Optional
: Change the polarization direction
2
of the antenna to horizontal.
Apply petroleum jelly around the exterior
3
side of the feed.
4
Connect the RTN 380H to a hybrid coupler.
Connect the hybrid coupler to an antenna.
5
Install the PGND cable of the RTN 380H.
6
7
Connect the P&E cable to a PI.
8
Install XPIC cascade cables.
•Do anti-corrosion treatment for XPIC cascade cables.
9
Install an outdoor fiber.
• Install an outdoor fiber on the RTN 380H.
• Lay out the outdoor fiber.
•Attach a yellow outdoor label to the fiber according to the plan.
•Moistureproof the fiber.
Do anti-corrosion treatment for COMBO ports, P&E ports,
10
XPIC ports and GE ports.
11
Waterproof the ground clip.
12
Check the installation.
20/21 >>
1到5
10
10
10
10
9
7
GE cable
XPIC cascade cable
Grounded using
a ground clip
11
6
10
10
11
7
Conn
ected
to a PI
8
8
Connected to one GE (optical) service
NOTE
The RTN 380H can receive power signals from
either the DC power port (PWR) or the P&E
port. Power over the P&E port is used as an
example.
Site commissioning procedure
Power on the RTN 380H.
1
Load NE data by using a USB
2
flash drive.
Use the Web LCT to load NE
3
data.
Align antennas.
4
5
6
10
10
11
Grounded through
the ground clip
9
NOTE
Install a PI by following
instructions in the PI Installation
Guide.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V100r008

Table of Contents