7 Operating the Application
7.3 Live demo
The "recipe" screen consists of an overview field with information on the selected
recipe data record (1) and an operator panel for the teaching function (2).
In the exported data blocks, a "wall anchor" recipe has been created for this
application with the following three data records:
1. Wall anchor 6mm x 200
2. Wall anchor 8mm x 100
3. Wall anchor 10mm x 50
Select the goods to be packaged via the data record no (3) or the arrow buttons.
As a result, the data information (4) is read from the load memory via the
"READ_DBL" function:
Data record name
Wall anchor diameter
Number of wall anchor
Individual weight of a wall anchor
Weight tolerance for the quality assessment of the quantity filled
Teach function
To determine the individual weight of a wall anchor, proceed as follows:
Table 7-2
No.
1.
Place a container on the load cell.
2.
Tare the scale.
3.
Fill the container with a counted number of
wall anchors.
4.
Enter the number of wall anchors in (6).
5.
Click the teach button (7).
6.
The weight is divided by the number of wall
anchors and indicates the individual weight
of one wall anchor.
The newly determined individual weight is
written in the selected recipe data record in
the exported "RECIPE_DB" data block via
the "WRIT_DBL" function.
7.
Then the entire recipe data records are
exported in the relocated "RECIPE_DB" data
block via the "RecipeExport" function in the
"RECIPE_DB.csv" file on the CPU web
server.
8.
Finally take the container from the scale and
delete the taring.
Weighing, Controlling and Logging (Set 6)
Entry ID: 82454336,
V2.0,
Action
10/2017
Comment
(5) displays the weight of
the wall anchors.