Electrical system

Engine control

Operation of system
Starting engine
When the starting switch is turned to the
"START" position, the starting signal flows to the
starting motor. Then, the starting motor turns to
start the engine.
When it happens, the engine controller checks
the signal voltage from the fuel control dial and
sets the engine speed to the speed set by the
fuel control dial.
Engine speed control
The fuel control dial sends a signal voltage cor-
responding to the rotation angle to the engine
controller.
The pump controller receives the fuel dial posi-
tion information from the engine controller
through the network.
The pump controller calculates the engine speed
in accordance with the working mode, the decel-
eration, and the like, and sends an instruction to
the engine controller.
The engine controller determines the fuel injec-
tion quantity based on the instruction received
from the pump controller.
2
10 Structure, function and maintenance standard
Stopping engine
When detecting that the starting switch is set to
the "STOP" position, the engine controller cuts
the fuel injection to stop the engine.