Quick Links

Warning: to prevent fire or shock hazard, do not expose
camera or monitor to rain or moisture.
The lightning flash with arrowhead
symbol, within a triangle, is intended to
alert the user to the presence of
uninsulated "dangerous voltage" within
the product's enclosure; that may be of
sufficient magnitude to constitute a risk
of electric shock to persons.
Caution: to reduce the risk of electric shock, do not remove
cover (or back). No user serviceable parts inside. Refer servicing
to qualified service personnel.
The exclamation mark within a triangle is
intended to alert the user to the presence
of important operating and maintenance
(servicing) instructions in the literature
accompanying the appliance.
Electro Magnetic Compatibility
(EMC)
This equipment complies with the European rules for
EMC according to EN55013, EN55020 and EN50082-1.
The equipment conforms with the EMC directive and
low-voltage directive.
This device complies with EMC rules under test
conditions that included use of system cables and
connectors between system components. If you have any
problems, contact your dealer.
Warning
Any unauthorized modification to this equipment may cause
violation of the EMC rules resulting in the revocation of the
authorization to operate the equipment.
Note: we advise you to use the following types of mains
power adapters in combination with the camera:
U.K.
Philips VCM1162/01R
EUR
Philips VCM1162/00R
1
Important notes for users in the U.K.
If the fitted plug is not suitable for your mains socket,
it should be removed and be replaced by an appropriate
plug.
How to replace a plug
Cut the mains plug from the lead.
Strip the sheathing so the wires will become free for
the necessary length to connect the UK-mains plug (not
supplied).
The wires in the mains lead are coloured according to
the following code: blue=neutral (N), brown=live (L).
As these colours may not correspond with the colour
markings identifying the terminals in your plug, proceed
as follows:
Connect the blue wire to the terminal marked N or
coloured black.
Connect the brown wire to the terminal marked L or
coloured red.
Caution
Do not connect either wire to the earth terminal in the
plug, marked E (or ) or coloured green (or green and
yellow).
Before replacing the plug cover, make certain that the
cord grip is clamped over the sheath of the lead, not
simply over the two wires.
Fuse
If the mains plug (or adapter) contains a fuse, the value
of this fuse should be 3 Amp. Alternatively, if another
type of plug (not fused) is used, the fuse at the
distribution board should not be greater than 5 Amp.

Advertisement

Table of Contents
loading

Summary of Contents for Philips VSS7374/D4T

  • Page 1 Note: we advise you to use the following types of mains power adapters in combination with the camera: U.K. Philips VCM1162/01R Philips VCM1162/00R Important notes for users in the U.K. If the fitted plug is not suitable for your mains socket, it should be removed and be replaced by an appropriate plug.
  • Page 2: Table Of Contents

    Colour Observation Quad Table of contents Introduction... 3 Connection and operation facilities... 4 Installation... 5 Camera Monitor Operation of the monitor... 5 Power on/off Power save/active Talk function Action function Freeze image View modes Camera selection System reset How do the menus work?... 7 Menu control buttons The menus...
  • Page 3: Connection And Operation Facilities

    Mains supply: The monitor accepts a mains power voltage of 100-240V~, 50/60Hz. For the camera(s) and system accessory boxes a safe low-voltage (16-32V ) is supplied by the Quad monitor through the system cable. The Quad monitor, camera(s) and accessories are automatically switched on when the Quad monitor is switched on with the rear mains switch.
  • Page 4: Installation

    camera in max 24V 2A video audio alarm gnd Camera inputs (1 to 4) VCR in/output The VCR output contains the image (full/quad) displayed on screen (no menu) and the sound of the selected camera input. Aux. output Output which contains the image and sound of one of the 4 camera inputs (menu controlled).
  • Page 5: Power Save/Active

    1 Power on The monitor switches ON. The following text appears on the monitor screen: PHILIPS OBSERVATION SYSTEM VERSION x.x SYSTEM CHECK (x.x = version number) After approximately 30 seconds or when a button is pressed the camera image appears on the monitor screen.
  • Page 6: Camera Selection

    Quad monitor, you can set the Quad monitor to the factory default settings. During a reset a beep sounds and the following text is shown on the monitor screen: PHILIPS OBSERVATION SYSTEM VERSION x.x SYSTEM RESET After approximately 30 seconds or when a button is pres- sed the message will disappear from the monitor screen.
  • Page 7: Silent Function On/Off

    Alarm function active yes/no (ALARM) With this function you can activate or deactivate the alarm function of the connected camera inputs. The alarm function of this camera input is activated. The alarm function of this camera input is not activated. In case an alarm box triggers an alarm, the buzzer, the alarm relay and the slave alarm information are not activated.
  • Page 8: Alarm Function

    The items of the install menu are discussed in the following sections. Display time and date (DISPLAY) With this option you can select if and where you want to display the time and date on the monitor screen (Lower left-hand corner, Lower right-hand corner or off). Select DISPLAY from the Install Menu;...
  • Page 9: Trouble Shooting

    The alarm information is sent to the slave monitor (optional) for max. 3 minutes. The history table is updated with the alarm event. 2 Monitor in power save mode: There are two possibilities: Non-silent mode (silent function off) The monitor switches to active mode, see ‘monitor in active mode’.
  • Page 10: System Cable

    For example the recording time of an E-180 tape - depending on the VCR type - is extended to one day or even one month. Philips provides several types of time-lapse VCRs. CL 66610005_006.AI...
  • Page 11: Technical Specifications

    Technical specifications S ystem monitor Picture tube 14", 90° deflection, 0.65mm pitch TV grade Resolution (Line pairs) 340 TVL TV standard PAL, 625 lines, 50Hz, 2:1 Mains supply voltage 100 - 240V Power consumption 70W max. (without cameras) 110W max. (with 4 cameras at 200m.) 16-32V Camera power supply System synchronisation...