GE Bently Nevada TK84 User Manual page 11

Temporary transducer interface
Table of Contents

Advertisement

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
TK84 Temporary Transducer Interface User Guide
4.
Install pickup holder, with optical
Keyphasor sensor attached, in the
end of the gooseneck. Tighten pickup
holder locking knob.
5.
Connect gooseneck to magnetic base,
using the threaded adapter. (An
alternate mounting method is with
the vise grip pliers. Do not use the
threaded adapter when connecting
gooseneck to vise grip pliers).
6.
Mount the magnetic base (or vise grip
pliers) on the machine.
7.
Loosen lever and adjust gooseneck so
pickup is about 3 inches from shaft.
Do not bend gooseneck more than 90
degrees.
8.
Tighten lever to secure gooseneck.
It may be necessary to adjust gooseneck
tension using tension adjustment. Loosen
lock nut and turn tension adjustment
clockwise (viewed from pickup end) to
tighten. Secure tension adjustment with
9.
Connect optical sensor cable to TK84
PROBE A connector.
10. Connect TK84 OUT A to a voltmeter (to
use the TK83 Balance Master 2> connect
to the SIGNAL connector in the
DIRECT/GAP mode).
11. Set TK84 CHAN A switch to ON. Make
sure BATTERY OK light is brightly lit
and not flashing.
6
NOTE
lock nut.

Advertisement

Table of Contents
loading

Table of Contents