Power Supply System Failure - HP 12500 Series Installation Manual

Routing switch
Table of Contents

Advertisement

Power supply system failure

Power monitor module
Table 27 Power monitor module LED description
LED
RUN
MAJOR
MINOR
To troubleshoot the failures when the RUN LED of the power monitor module is off:
Unplug and then plug the power monitor module.
1.
If the RUN LED is still off, replace the power monitor module.
2.
If the RUN LED is still off, contact HP Technical Support for help.
3.
Power supplies
Figure 58 LEDs on an AC power supply
(1) Input status LED
Status
Description
Steady on
The power monitor module is operating properly.
Off
The power monitor module is faulty.
At least one power supply is faulty.
The switch of the power frame is off.
Steady on
A power supply is present, but no AC power supply is provided.
Turns on and
A power supply is being inserted or removed.
then goes off
Off
The power supplies are operating properly.
Off
Reserved
(2) Output status LED
(3) Over-temperature alarm LED
80
1
2
3
4
(4) Fault LED

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

125081250412518

Table of Contents