An energy-saving profile runs through the displayed automatic state machine if the associated
"energy-saving profile initialized" bit is set. The HMI resets this bit before changing the times
or the signal mask, and sets it after the values have been consistently written into the PLC.
When the "Energy-saving profile active" bit is set, then an energy-saving profile is considered
to have been assigned.
Figure 4-1
Transition to "RUN"
All of the signals that have been enabled for evaluation using the following masking bits, are
inactive
(also see Chapter 3.1.5.2.):
DBX 11.0, DBX 11.1, DBX 11.2
DBX 12.0
DBX 13.0 – DBX 13.7
DBX 14.0, DBX 14.1
DBX 15.0, DBX 15.1
The specified signals refer to energy-saving profile 1.