The behavior for different signal sequences of both measurement control signals are described
in the following:
● DBX1.0 is set first
If DBX1.0 ("MeasAuto") is first set, and then remains statically present, every 0-1 edge of
DBX2.0 ("MeasAct") deletes the measured value and then starts the measurement.
If DBX2.0 is reset, the measurement is canceled and the measured value remains constant.
The sequence is repeated at the next 0-1 edge of DBX2.0.
Figure 3-3
● DBX2.0 is set first
If DBX2.0 ("MeasAct") is set first, and then remains statically present, every 0-1 edge of
DBX1.0 ("MeasAuto") accumulates the measured value without deleting the previous value.
If DBX1.0 is reset, the measurement is only interrupted and the measured value remains
constant.
Figure 3-4
3.3.2

Configuring the display of energy consumption for SINUMERIK 828D

The energy consumption is displayed in the "SINUMERIK Ctrl-E Analysis" window.
See also
Signals for controlling energy-saving profiles (Page 46)
Signals for parameterization (Page 47)
Ctrl-Energy
System Manual, 01/2015, 6FC5397-0EP40-5BA2
Measurement control signal DBX1.0 is set first
Measurement control signal DBX2.0 is set first
3.3 Commissioning the PLC for Ctrl-E Analysis
Ctrl-E Analysis
29