TESTING THE POWER BOARD RELAYS
To test the operation of the relays on the power board, turn power off and disconnect the wires from
the terminals indicated in the chart, then connect the voltmeter test leads to the board terminal and
the wire connector under test, and apply power to the cooktop.
VAC
Orange / White
Orange / Black
Brown / White
Relay No.
1
2
3
4
7
All manuals and user guides at all-guides.com
WARNING
Electrical Shock Hazard
The following tests require power to be ap-
plied to the cooktop. Use only the meter test
probes and touch the points indicated in the
chart. Do not touch the board with your
fingers.
Failure to do so could result in electrical
shock or other personal injury.
Relay
P2
2
Relay
7
P6
Relay
4
P10
VAC
P16
VAC
Terminal No.
Wire Color
P 2 0
Blue/White
P 6
Orange/White
P 1 7
Tan/White
P 1 6
Brown/White
P 1 0
Orange/Black
1
6
P4
P3
P1
U1
Relay
U2
1
Relay
3
P20
VAC
P17
VAC
Element ON HIGH
240 VAC
240 VAC
240 VAC
240 VAC
240 VAC
4-7
1
JP2
Blue / White
Tan / White
Element OFF
0 VAC
0 VAC
0 VAC
0 VAC
0 VAC