MEMORY ALL CLEAR
Use this function to delete all stored settings from memory.
Operation
While the power is ON (pilot lamp is lit in green), press and hold down the STORE button and
then press the ON/STANDBY switch to set this unit to Standby mode (pilot lamp is lit in red).
When the power of the system is switched ON next time, all settings will be cleared from memory. The settings of the
Crosspoint buttons will be reset to their default settings.
NOTE
Individual settings cannot be deleted from memory.
Check carefully when you use the MEMORY ALL
CLEAR function.
Default Setting
By default the indicators are set as follows:
Input channel 1 is selected for all output channels.
LAST MEMORY
With the PVS-1240S, the LAST MEMORY function is always active so that the latest settings can be restored. Use this function if
this unit was unintentionally set to Standby mode from power ON, or if the POWER switch was set to OFF by mistake. The
previous settings will be restored when this unit is switched ON next time. This function is permanently active due to the
nonvolatile memory.