Siemens SITRANS LG260 Operating Instructions Manual page 71

Guided wave radar. four-wire modbus converter version in second chamber rod and cable probe
Hide thumbs Also See for SITRANS LG260:
Table of Contents

Advertisement

Protection rating
Ʋ unassembled
Ʋ mounted in the housing without lid
Materials
Ʋ Housing
Ʋ Inspection window
Functional safety
Integrated clock
Date format
Time format
Time zone, factory setting
Max. rate deviation
Additional output parameter - Electronics temperature
Output of the values
Ʋ Indication
Ʋ Analogue
Ʋ Digital
Range
Resolution
Accuracy
Voltage supply
Operating voltage
Power consumption
Reverse voltage protection
Potential connections and electrical separating measures in the instrument
Electronics
Ground terminal
Galvanic separation between electronics and metal housing parts
Ʋ Reference voltage
Electrical protective measures
Protection, depending on housing version
Ʋ Plastic housing
Ʋ Aluminium housing; stainless steel
housing - Precision casting
Connection of the feeding power supply
unit to networks of overvoltage category
PBD-51041059
IP 20
IP 40
ABS
Polyester foil
SIL non-reactive
Day.Month.Year
12 h/24 h
CET
10.5 min/year
Via the display and adjustment module
Via the current output
Via the digital output signal (depending on the electron-
ics version)
-40 ... +85 °C (-40 ... +185 °F)
< 0.1 K
±3 K
8 ... 30 V DC
< 500 mW
Integrated
Not non-floating
Galvanically connected with the metal process fitting
500 V AC
IEC 60529 IP 66/IP 67 (NEMA Type 4X)
IEC 60529 IP 66/IP 68 (0.2 bar), NEMA Type 6P
III