5 Hardware Drive Functions
5.3 Notes
5.3.2

Transport and storage conditions

Relevant
standards
Originally
packaged modules
5-186
Note
The following information refers to the electrical section of the HLA.
IEC 68-2-1, IEC 68-2-2, IEC 68-2-3
The following data applies to modules in their original packaging:
Table 5-8
Climatic conditions
Temperature range
Dew-point temperature td
and relative air humidity U
Condensation
Temperature rate of
change
Air pressure
Table 5-9
Mechanical conditions during transportation in original packaging
Vibration resistance (to
IEC 68-2-6)
SINUMERIK 840D/SIMODRIVE 611 digital, HLA Module (FBHLA) - 10.03 Edition
Lower limit temperature
Upper limit temperature
Annual average
On 30 days (24 hours) in
year (days distributed over
the annual period)
On 30 days (24 hours) in
year (days distributed over
the annual period)
As regards condensation,
the following conditions may
apply simultaneously:
Max. condensation period
Frequency of condensation
Shortest sequence of con-
densation cycles
Within one hour
The specified values apply
to a transportation altitude
of up to 3265 m above sea
level
Frequency range
5 - 9 Hz
Over 9 - 500 Hz
 Siemens AG, 2003. All rights reserved
02.99
10.03
-40 °C
+70°C
U = 75%, td = 17°C
U = 95%, td = 24°C
U = 85%, td = 20°C
Seldom, brief, slight
3 hours
Annual average 3/Max.: 10
1 day
20 K
66 kPa to 108 kPa
Const. Deflection
3.5 mm
Ampl. of acceleration
2
10 m/s

Hide quick links: