SEN04121-02
Failure code [DWJ0KB] Merge-divider sol short
User code
Failure code
—
DWJ0KB
Contents of
• When merge-divider EPC solenoid was driven, short circuit was detected in circuit.
trouble
Action of
• Turns output to merge-divider EPC solenoid OFF.
controller
• Even if cause of failure disappears, system does not reset itself until starting switch is turned OFF.
Problem that
appears on
• Single operation speed of work equipment and swing is high in lifting mode (L).
machine
Related
• Method of reproducing failure code: Turn starting switch ON.
information
Defective merge-divider EPC
1
solenoid (Internal short cir-
cuit or ground fault)
Possible causes
Ground fault in wiring har-
and standard
2
ness (Short circuit with GND
value in normal
circuit)
state
3 Defective pump controller
38
Merge-divider solenoid short
Trouble
(Pump controller system)
Cause
Standard value in normal state/Remarks on troubleshooting
a Prepare with starting switch OFF, then carry out troubleshoot-
Between (2) – chassis ground
a Prepare with starting switch OFF, then carry out troubleshoot-
Wiring harness between CP02 (female)
(112) – V02 (female) (2) and chassis ground
a Prepare with starting switch OFF, then carry out troubleshoot-
Between (112) – (115), (117),
Between (112) – chassis ground
ing without turning starting switch ON.
V02 (male)
Between (1) – (2)
ing without turning starting switch ON.
ing without turning starting switch ON.
CP02 (female)
(120)
40 Troubleshooting
1
Resistance
20 – 60 z
Min. 1 Mz
Resis-
Min. 1 Mz
tance
Resistance
20 – 60 z
Min. 1 Mz
PC130-8